$583.99 cheaper than the new price!!
Management number | 203021803 | Release Date | 2025/09/21 | List Price | $584.00 | Model Number | 203021803 | ||
---|---|---|---|---|---|---|---|---|---|
Category |
Introduction:
This is a multi-function inverter/chargei; combining functions of inverter solar charger and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority and acceptable input voltage based on different applications.
Note:
Please Only Use Sealed Lead Acid Battery Or Sealed GEL/AGM Lead-Acid Battery.
The new package is no CD disc, but we have the software, if you need it , feel free to contact us.
Features:
Pure sine wave inverter
Built-in PWM solar charge controller
Configurable input voltage range for home applicances and personal computers via LCD setting
Configurable battery charging current based on applications via LCD setting
Configurable AC/Solar charger priority via LCD setting
Compatible to mains voltage or generator power
Auto restart while AC is recovering
Overload/over temperature/ short circuit protection
Smart charging system optimizes battery performance
Cold start function
Product Parameter:
SPECIFICATIONS | |
Table 1 Line Mode specifications | |
INVERTER MODEL |
3KVA |
Input Voltage Waveform |
Sinusoidal (Utility Or Generator) |
Nominal Input Voltage |
120Vac |
Low Loss Voltage |
95Vac±7V (UPS);
65 Vac±7V (Appliances)
|
Low Loss Return Voltage |
100Vac±7V (UPS);
70Vac±7V (Appliances)
|
High Loss Voltage |
140Vac±7V |
High Loss Return Voltage |
135Vac±7V |
Max AC Input Voltage |
150Vac |
Nominal Input Frequency |
50Hz / 60Hz (Auto Detection) |
Output Short Circuit Protection |
Circuit Breaker |
Efficiency (Line Mode) |
>95% ( Rated R Load, Battery Full Charged ) |
Transfer Time |
10Ms Typical (UPS);
20Ms Typical (Appliances)
|
Table 2 Inverter Mode specifications | |
INVERTER MODEL |
3KVA |
Rated Output Power |
3KVA/2.4KW |
Output Voltage Waveform |
Pure Sine Wave |
Output Voltage Regulation |
120Vac±5% |
Peak Efficiency |
90% |
Overload Protection |
5S@≥150% Load;
10S@110% R 150% Load
|
Surge Capacity |
2* Rated Power For 5 Seconds |
Nominal DC Input Voltage |
24Vdc |
Cold Start Voltage |
23.0Vdc |
High DC Recovery Voltage |
29Vdc |
High DC Cut-Off Voltage |
31Vdc |
No Load Power Consumption |
<20W |
Saving Mode Power Consumption |
<10W |
Table 3 charge Mode specifications | |
Utility Charging Mode |
Utility Charging Mode |
AC Charging Current |
20/30Amp
(@V I/P= 120Vac)
|
Floating Charging Voltage |
27Vdc |
Solar Charging Mode |
Solar Charging Mode |
Charging Current (PWM) |
50Amp |
System DC Voltage |
24Vdc |
Operating Voltage Range |
30~32Vdc |
Max. PV Array Open Circuit Voltage |
80Vdc |
Standby Power Consumption |
2W |
DC Voltage AccurACy |
+/- 0.3% |
Battery Connection | |||||||
Model |
Typical Amperage |
Battery Capacity |
Wire Size |
Ring Terminal |
Torque value |
||
Cable mm2 |
Dimensions |
||||||
D(mm) |
L(mm) |
||||||
3KVA |
100A |
100AH |
1*4AWG |
22 |
6.4 |
33.2 |
2~3 Nm |
200AH |
2*8AWG |
14 |
6.4 |
29.20 |
|||
AC Input/Output Connection | |||||||
Model |
AC Breaker |
Gauge |
Torque value |
||||
3KVA |
32A |
12 AWG |
1.2~1.6 Nm |
||||
PV Connection | |||||||
Model |
Typical Amperage |
Gauge |
Torque value |
||||
3KVA |
50A |
8 AWG |
1.4~1.6 Nm |
||||
PV Module Selection | |||||||
Maximum Power(Pmax) |
260W |
Max.PV module numbers in series |
|||||
Max. Power Voltage Vmpp(V) |
30.9V |
1: 30.9x1=30~32 |
|||||
Max.Power Current Impp(A) |
8.42A |
PV module numbers in parallel |
|||||
Open Circuit Voltage Voc(V) |
37.7V |
6: 50A/8.42 |
|||||
Short Circuit Current Isc(A) |
8.89A |
Total PV module numbers:1x6=6 |
|||||
Maximum PV module numbers in Series :1 | |||||||
PV module numbers in parallel :6 | |||||||
Total PV module numbers :1x6=6 |
If you notice any omissions or errors in the product information on this page, please use the correction request form below.
Correction Request Form